DENSITOMETER

  • Compact benchtop densitometers for measuring cell suspension turbidity in life science applications.
  • Measurement Range: 0.00 to >15.00 McFarland units with +3% precision.
  • Fast Results: Measurement time of just 1 second.
  • Bright LED Display: Clear McFarland unit readings.
  • Factory Calibrated: Retains calibration even without power.
  • User Calibration: Compatible with commercial standards or lab-prepared suspensions.
  • Tube Compatibility: Designed for 18mm tubes, with optional adapters for 16mm
    (D-16 included) & 12mm (A-12 sold separately).
  • Space-Saving Design: Small footprint, ideal for limited workspaces.
  • Power Options (DEN-1B Only): Operates on 3 x AAA batteries or external power supply.

Application

Cell Concentration Measurement

Accurate estimation of bacterial and yeast cell density during fermentation processes.

Fermentation Monitoring

Supports real-time tracking of microbial growth and process consistency.

Antibiotic Susceptibility Testing

Used to assess microbial response and sensitivity to antibiotics.

Microorganism Identification

Aids in identifying microorganisms using standardized test systems.

Quality Control in Microbiology

Ensures reliable, repeatable measurements for research, clinical, and industrial labs.

SpecificationDEN-1DEN-1B
Dimensions (H × D × W)75 × 115 × 165 mm75 × 115 × 165 mm
Temperature Range+4 to 40°C+4 to 40°C
Light SourceLEDLED
Wavelength565 ±15 nm565 ±15 nm
Measurement Range (McFarland Units)0.00 to >15.000.00 to >15.00
Precision±3%±3%
Measurement Time1 sec1 sec
Tube Diameter (External)18 mm18 mm
Tube Diameter (with D16 Adapter)16 mm16 mm
Sample Volume> 2 ml> 2 ml
Display / ResolutionLED / 0.1 McFLED / 0.1 McF
Independent Power SupplyExternal power supply:
Input AC 120–230 V, 50/60 Hz
Output DC 12 V
3 × AA batteries
OR External power supply:
Input AC 120–230 V, 50/60 Hz
Output DC 12 V
Power Consumption (230 V)1 W (0.08 A)0.1 W (0.007 A)
Weight0.7 kg0.7 kg
Cat No.Description
DEN-1Densitometer for cell density / turbidity measurement
(0.0 – 15.0 McFarland units), suitable for 16 mm or 18 mm tubes
(D16 adapter included).
DEN-1BPortable densitometer (battery / mains powered) for cell density /
turbidity measurement (0.00 – 15.00 McFarland units), suitable for
16 mm or 18 mm tubes (D16 adapter included).
Cat No.Description
D16Adapter replacement for 16 mm outer diameter tubes; compatible with
DEN-1 and DEN-1B.
DEN MCF STDSStandards reference set of 5 McFarland units for user calibration of
16 mm tubes (requires D16 adapter).
A12 NEW12 mm adapter for use with DEN-1B.
Scroll to Top